Anti-backsplash valve
Anti-backsplash valve KMT 5001-SN-1 Aqualon 12878. Peça compatível para sistemas de corte por jato de água (BFT > Waterjet Cutting Heads), disponível na Herramentalia com preço online ou consulta técnica.
Source: Aqualon
Quick references
- Aqualon article
- 12878
- Other references
- 5001-SN-1
- Aqualon compatibility
- BFT / Waterjet Cutting Heads +14
Empresa ou profissional? Consulte o seu preço especial.
Source: Aqualon
Equivalent references
Aqualon article
12878
- Other references
- 5001-SN-1
- Extracted references
- 5001-SN-1
- Aqualon article number
- 12878
Net weight
Weight pending review
Detected technical measurements
Source: Aqualon
Technical features
- Purpose: Stops water from traveling up the abrasive feed hose into the mini-hopper.
- Causes of Water Backflow: Worn-out or leaking on-off valve. Worn-out mixing chamber in the cutting head. Nozzle positioned too close to the material (less than 1/8”).
- Worn-out or leaking on-off valve.
- Worn-out mixing chamber in the cutting head.
- Nozzle positioned too close to the material (less than 1/8”).
- Common Names: ABRA Line, Water Stopper, Anti-Backwash Valve.
Pedir orçamento
Contacte-nos para orçamentos, suporte técnico ou qualquer questão